Quick Checks
# Check for running instances (DO THIS FIRST when debugging stale data)
ps aux | grep tentacle
# Kill all tentacle processes
pkill -f tentacle
# Check NATS is running
nats server info
# Check service heartbeats
nats kv get service_heartbeats ethernetip
# Watch all variable data in real-time
nats sub "*.data.>"
# Watch modbus data for a specific device
nats sub "modbus.data.my-device"
# Check NATS KV cache
nats kv get field-config-{projectId} cache.variables.{variableId}
Common Issues
Stale data appearing after refresh
Symptom: Old values appear even after restarting services
Cause: Multiple instances of a scanner running simultaneously. NATS requests can be answered by ANY running instance.
Fix:
ps aux | grep tentacle
pkill -f tentacle
# Then restart only the services you need
MQTT not publishing / values look "flat"
Symptoms:
- MQTT values don't change even though device values are changing
- Sparkplug client shows constant values
Causes & Fixes:
- Deadband filtering: Values changing by less than deadband won't publish. Check
mqtt-config-{projectId}KV bucket - Variable not enabled: Verify variable is enabled in mqtt-config
- Data IS being read: Check the 30s status log in the scanner — it shows sample values
DCMD commands not working
Symptom: Write commands from Ignition/SCADA don't reach the device
Debugging steps:
- Check tentacle-mqtt logs for "Received DCMD" message
- If no DCMD log: synapse version issue (need 0.0.87+)
- If DCMD received but not forwarded: wrong event signature
- Check scanner logs for write attempts
Common causes:
- Wrong synapse version (need 0.0.87+ for reconnection fixes)
- MQTT reconnection dropped DCMD subscription
- NATS publish encoding issue (must use
TextEncoder().encode())
EtherNet/IP not polling tags
Symptom: No data from PLC, tags show as "unknown" or 0
Causes & Fixes:
- No subscription: Only polls tags with active subscriptions (from MQTT config or tentacle-plc)
- Connection failed: Check logs for connection errors, verify PLC IP
- Browse first: Tags must be discovered via browse before they can be subscribed
Modbus not reading values
Symptom: Modbus device shows no data; scanner connects but no modbus.data.* messages
Causes & Fixes:
- No subscription sent: The scanner only polls after a
modbus.subscriberequest arrives - Wrong function code: Verify FC matches register type (coils vs. holding registers)
- Address off-by-one: Modbus addresses are 0-based in tentacle-modbus. Some tools show 1-based addresses — subtract 1
- Byte order: Default is ABCD (big-endian). CoDesys and some devices use CDAB or BADC — check
byteOrderin tag config - PDU byte offset: Response is
[FC, ByteCount, Data...]— data starts at byte index 2
Debugging:
# Watch modbus subscribe/unsubscribe requests
nats sub "modbus.>"
# Check modbus scanner logs
nats sub "service.logs.modbus.>"
OPC UA (tentacle-opcua-go) certificate issues
Symptom: Bad_CertificateUseNotAllowed from Ignition/Eclipse Milo
Cause: Self-signed cert missing required key usage bits for Milo's strict validation.
Required cert properties:
KeyUsageCertSign(bit 5) must be set — even for self-signed- AKI must equal SKI
- ExtKeyUsage:
clientAuth+serverAuth - SAN must include ApplicationURI
See troubleshooting OPC UA for cert generation commands.
Ignition OPC UA connection refused
Symptom: OPC UA client connects but gets "endpoint not found" or connection refused
Fix: In Ignition, add the hostname your client uses to connect:
Config → OPC UA → Server → Endpoint Addresses
GraphQL subscriptions stale
Symptom: Web UI not updating in real-time
Fixes:
- Check
service_heartbeatsKV for service health:nats kv get service_heartbeats graphql - Verify tentacle-graphql is connected to NATS
- Check browser console for SSE connection errors
- Check that
*.data.>subscription is active in tentacle-graphql
Service not appearing in topology
Symptom: Service is running but not visible in the web topology view
Cause: Service heartbeat not being published to service_heartbeats KV
Debugging:
# List all heartbeats
nats kv watch service_heartbeats
# Check if a specific service is publishing
nats kv get service_heartbeats {moduleId}
Service not receiving NATS messages
Debugging:
- Verify topic patterns match between publisher and subscriber
- Use
nats sub "*.data.>"to see what's being published - Check service
.env—NATS_SERVERSmust match
Debug Mode
# Verbose output for Deno services
LOG_LEVEL=debug deno task dev
Cache Issues
NATS KV delete() just adds a tombstone marker. For complete removal:
# In code
await kv.purge(key);
# Or start with clean cache (EtherNet/IP)
deno run -A main.ts --clear-cache
Bugs Previously Fixed (Don't Reintroduce!)
1. Wrong UDT member datatypes (EtherNet/IP)
Symptom: VALUE showing as "boolean" instead of "number"
Root cause: decodeTagValue() checked cached datatype BEFORE typeCode from PLC response
Fix: Prioritize typeCode from actual PLC response over cached datatype
Location: tentacle-ethernetip/scanner.ts decodeTagValue() function
2. Newly enabled MQTT tags not being polled (EtherNet/IP)
Root cause: autoSubscribeMqttTags() only called at startup, not on config changes
Fix: Added handleMqttConfigChange() that syncs subscriptions when MQTT config changes
3. Modbus wrong PDU data offset
Symptom: All Modbus values read as 0 or garbage
Root cause: Modbus response PDU is [FC, ByteCount, Data...] — data starts at offset 2, not 1
Fix: Use offset 2 in extractBits() / extractWords() calls
4. Modbus stale readLoop closes new connection
Symptom: Modbus reconnection fails; connection closes immediately after reconnect
Root cause: Old readLoop callback runs .catch() after reconnect and calls handleDisconnect() on the new connection
Fix: Generation counter — connect() increments generation; readLoop .catch() checks if (this.generation !== gen) return